The Polaris DP-30 is the perfect way to introduce new technology and ease of operation to your existing line. Fife makes it easy to update your existing CDP-01 Web Guide Controllers with this new technology by keeping the same cabling, mounting dimensions and bolt pattern, and by offering convenient retrofit packages. Available for both electromechanical and electrohydraulic operations, the Polaris DP-30 can be configured for line, edge, or center guiding applications.

Description

FIFE POLARIS DP-30 WEB GUIDE CONTROLLER SPECIFICATIONS

[tabbed_section style=”default” alignment=”left” spacing=”default” tab_color=”Accent-Color”][tab icon_family=”none” title=”Imperial” id=”1590476441242-9″ tab_id=”1590476441243-8″]
  • Weight8 lb
  • Power Input90 VAC to 264 VAC
  • Input Line Frequency47 to 63 Hz
  • Power Consumption180 VA
  • Internal Fuse3.15 Amps
  • Maximum Actuator Output80 W
  • Maximum Lockout Valve Output39 W at 24 V or 48 V
  • Motor Current Capacity2.6 Amps
  • IP ProtectionIP54
  • Current Source Output+/- 50 mA for Hydraulic Servo Valve
  • Supply to Accessories+12 V +/-5%, 600 mA, -12 V +/-5%, 150 mA
  • Parallel I/OSix Digital Inputs Referenced to Group, (24 V max, 6 mA),
    and Two Open Collector Outputs, (30 V max, 55 mA)
  • Servo CenterAnalog Inductive Type
  • Operating Temperature0 to 50˚ C
[/tab][tab icon_family=”none” title=”Metric” id=”1590476441263-10″ tab_id=”1590476441263-9″]
  • Weight3.5 kg
  • Power Input90 VAC to 264 VAC
  • Input Line Frequency47 to 63 Hz
  • Power Consumption180 VA
  • Internal Fuse3.15 Amps
  • Maximum Actuator Output80 W
  • Maximum Lockout Valve Output39 W at 24 V or 48 V
  • Motor Current Capacity2.6 Amps
  • IP ProtectionIP54
  • Current Source Output+/- 50 mA for Hydraulic Servo Valve
  • Supply to Accessories+12 V +/-5%, 600 mA, -12 V +/-5%, 150 mA
  • Parallel I/OSix Digital Inputs Referenced to Group, (24 V max, 6 mA),
    and Two Open Collector Outputs, (30 V max, 55 mA)
  • Servo CenterAnalog Inductive Type
  • Operating Temperature0 to 50˚ C